9
Remote Annex Quick Start for Windows
166-024-858 Rev. A
Using the na Utility
You can also configure Remote Annex ports with the na utilities as shown
in the following examples involving non-RA 6300 Annexes installed
using default selections.
Modems
Annex supports inbound, outbound and inbound/outbound modems.
When entering port speed, set the highest speed supported by the modem.
Do not select autobaud.
Set the port parameters using na:
% na
command: annex 192.9.200.62
command: port 6
command: set port speed 115200
command: set port control_lines modem_control
command: set port input_flow_control start/stop
command: set port output_flow_control start/stop
command: set port type dial_in
Inbound Modem
command: set port mode auto_detect
Outbound Modem
command: set port mode slave
Inbound/Outbound
command: set port mode auto_adapt
command: reset port 6
command: quit