Installing the BayStack Advanced Remote Node
114200 Rev. A 1-21
Connecting a Terminal Console
You need both pieces in the ARN console/modem cable kit (Order No. 110310) to
connect a terminal console:
Order No. 110307 serial console/modem cable (with 9-pin receptacle to
25-pin plug connectors)
Order No. 110308 null modem crossover adapter (with two 25-pin receptacle
connectors)
Once you have the appropriate equipment, complete the following steps:
1. Power on and configure the console, using the parameters in Table 1-3.
Refer to the console user manual for instructions.
2. Power off the console.
3. Attach the null modem crossover adapter to the 25-pin cable connector.
4. Insert the screw on the cable connector into the receptacle on the adapter
connector and tighten the screw (F
igure 1-14).
Figure 1-14. Attaching the Null Modem Adapter
Table 1-3. Console Parameters
Parameter Value
Baud Rate 9600
Data Bits 8
Stop Bits 1
Parity None
Null modem adapter
Console cable
Screw receptacle
Rotate to tighten screw
AN0010A