Connectors and Pin Assignments
893-00992-A B-5
DB-9 (RS-232-D) Service Port Connector
The DB-9 service port connector (see Figure B-4) is configured as a data
communications equipment (DCE) device connector. The DSR and CTS signal
outputs are always asserted. The CD, DTR, RTS, and RI signal inputs are not
used. This arrangement allows a management station (a PC or terminal) to directly
connect to the switch using a straight-through cable.
Figure B-4. DB-9 service port connector
Table B-2 shows the service port connector pin assignments.
Table B-2. Service port connector pin assignments
Pin Signal Description
1 CD Carrier detect (not used)
2 TXD Transmit data (output)
3 RXD Receive data (input)
4 DTR Data terminal ready (not used)
5 GND Signal ground
6 DSR Data set ready (output always asserted)
7 RTS Request to send (not used)
8 CTS Clear to send (output always asserted)
9 RI Ring indicator (not used)
Shell Chassis ground
5
6
9
1
619EA
BOOK.MKR Page 5 Tuesday, March 4, 1997 7:24 PM