Configuring the Nortel Networks Remote Access Concentrators and the DMS-10 for Remote Access.March 31, 1999 15
A typical command would be “show port all”. This command will show all the port set-
tings.
Annex commands deal with generic system items such as:
• IP addresses
• CLI and VCLI parameters
• Name Servers
• Security
• Event Logging
• Routing
• SNMP Maintenance
Wan of course deals with the two T1 based WAN’s. In the WAN section the T1 character-
istics are set up along with B channel parameters.
Following any changes it is necessary to reset the device or in some cases boot the RAC to
make the parameter change take effect.
5.5.2 Setting the Initial Parameters.
The initial parameters are set using the Console monitor in the ROM monitor portion or
the RAC. This information is covered in the publication “Installing the Model 8000
Remote Access Concentrator”. This document covers setting the RAC into its initial setup
mode, it also covers the requirements for the IP addresses and supplementary information.
Figure 7 gives a view of the parameters and their significance.
FIGURE 7. Initial Address Setup
monitor:: addr
Enter Subnet mask [255.255.255.0]::
Enter Internet address [<uninitialized>]:: 47.39.240.40
Internet address 47.39.240.40
Enter Broadcast address [0.0.0.0]:: 47.39.240.00
Broadcast address 47.39.240.00
Enter Preferred Load Host address [<any host>]:: 47.39.240.99
Preferred Load Host address 47.39.240.99
Enter Preferred Dump Host address [0.0.0.0]:: 47.39.240.99
Enter Preferred Dump Host address 47.39.240.99
Enter Load/Dump Gateway address [<uninitialized>]:: 47.39.240.1
Enter Load/Dump Gateway address 47.39.240.99
Select type of IP packet encapsulation (ieee802/ethernet)
[<ethernet>]::
Load Broadcast Y/N [Y]::
This value sets the IP address the RAC will use for it’s connection
This value is the submet mask for the subnet the RAC is on.
This address is address the RAC uses to communicate with a security
of file server.
This is the address of the file server which serves as the load file
host for the RAC.
This is the address of the file server which serves as the dump file
host for the RAC.
Gateway address for the RAC. Serves as a route as well as a gateway
it the RAC’s file server is on a different subnet.
Setting up the initial addresses in the ROM monitor